Waterproofing
Foundation Waterproofing Calculator
Cement-based waterproof coating for foundation walls from perimeter, height and the data-sheet rate per coat, in whole bags
Updated October 10, 2026 · Live
What this tool does
Works out a cement-based waterproof coating for below-grade foundation walls: the wall area from the foundation perimeter and the height coated, the mass from a first-coat rate and a later-coat rate read off the product data sheet, wastage, whole bags or pails of the size you buy, how much one bag covers with all coats, and the cost at your price per bag. Rates in lb/yd² or kg/m²; results in both unit systems.
Perimeter times height gives the wall area; area times the summed coat rates gives the coating mass; plus wastage, rounded up to bags.
People also use
Formula Used
Formula Used
How the foundation waterproofing calculator works
A cement-based waterproof coating is bought by the bag and applied by the coat, so the quantity is the wall area times the rate for each coat, added up, plus an allowance, rounded up to whole bags. The area is the foundation perimeter times the height of wall to be coated. In the United States that height is set by the International Residential Code: section R406.2, as published on UpCodes (Virginia IRC 2021), says that where "a high water table or other severe soil-water conditions are known to exist", exterior foundation walls that retain earth and enclose space below grade "shall be waterproofed from the finished grade to the higher of the top of the footing or 6 inches (152 mm) below the top of the basement floor", and it lists the acceptable systems, among them a "one-eighth-inch (3 mm) cement-based, fiber-reinforced, waterproof coating", 40-mil polymer-modified asphalt, 60-mil flexible polymer cement and 60-mil liquid-applied synthetic rubber. Where no such conditions are known, section R406.1 asks for dampproofing over the same height instead. The rates come from the product data sheet: Sika's Thoroseal-581 sheet gives 2 lb/yd² (1.1 kg/m²) for the first coat and 1 lb/yd² (0.54 kg/m²) for the second, 3 lb/yd² (1.6 kg/m²) in all for a cured thickness of 1/16 in (1.6 mm), and prints the same thing as 225 ft² and 450 ft² per 50 lb bag. The calculator takes a first-coat rate and a rate for each later coat for that reason.
The US default is a 140 ft perimeter coated 8 ft down, 1,120 ft² (104.1 m²), at 2 then 1 lb/yd² in two coats: 3 lb/yd² (1.63 kg/m²) in all, 373.3 lb of coating, 410.7 lb with 10% wastage, and nine 50 lb bags, each bag covering 150 ft² with both coats. The metric default is a 40 m perimeter coated 2.4 m down, 96 m², at 1.5 kg/m² per coat in two coats: 288 kg, 316.8 kg with wastage, and thirteen 25 kg bags, each covering 8.3 m² with both coats.
Rates, coats and bags
Makers print a rate per coat and a minimum number of coats, and the two together are the figure to enter. The SikaTop-107 Seal data sheet gives 1.0 to 1.5 kg of mixed product per m² per coat by brush, says "2 coats always required" with the first on a pre-wetted substrate and the second brushed crosswise, caps a coat at 2 kg/m², and comes as a 25 kg two-part set; that is the source of the 1.5 kg/m² metric default. Sika's Thoroseal Plus sheet gives, for exterior walls exposed to rain and standing water, 0.22 lb/ft² (1.07 kg/m²) for the first coat and 0.11 lb/ft² (0.54 kg/m²) for the second, 160 and 320 ft² per 35 lb pail, and notes that "the yield of the mixed product will depend on the texture and porosity of the surface", which is what the wastage input is for: a rough block wall takes more than the sheet rate, and a smooth poured wall takes about the rate. Thoroseal-581 comes in 50 lb bags, Thoroseal Plus in 35 lb pails and 7 lb cans, and the bag-size input takes whichever is bought.
UK and the rest of the world
In the United Kingdom the same coating is a Type A barrier under BS 8102:2022, the British code of practice for protecting structures against water from the ground. Sika's basement waterproofing concept page summarises the standard's three types: Type A, a barrier applied to the external or internal face of the structure, including "post applied waterproofing mortars and coatings"; Type B, the structure itself made watertight; and Type C, cavity drainage to a sump and pump. It also notes the standard's suggestion of two types together where the risk or the consequence of failure is high. The Building Regulations in England, in paragraph 3.2 of Approved Document C, add that where the water table can rise to within 0.25 m of the lowest floor, the ground under the building should be drained or other effective means taken, which is the English counterpart to the IRC's "high water table" trigger. Other countries set their own rules for when a below-grade wall is waterproofed and how far down; the arithmetic on this page does not depend on them, only the height does. A liquid-applied elastomeric membrane for walls under hydrostatic pressure is a different product class, specified in the United States by ASTM C836 and sold by the gallon on its own coverage table, and is sized with the liquid rubber calculator rather than here.
What this tool does not do
It coats a plain wall of one height all round. It does not deduct openings, add for footings, pile caps or the kicker at the base of the wall, or count the fillets, primers, protection boards, drainage boards and footing drains that go with a below-grade system. It does not choose between external and internal application, which the makers treat differently, and it does not say whether a wall needs waterproofing or dampproofing; that is a ground-condition question for the designer and the local authority.
Adjusting the defaults
Every input is editable. The perimeter is the outside length of the foundation walls and the height is the depth from finished grade to the top of the footing, or whatever height the specification says to coat. The first-coat rate and the later-coat rate are read from the data sheet in lb/yd² (US units) or kg/m² (metric); where the sheet gives square feet per bag, the rate is the bag weight divided by that area, so 225 ft² per 50 lb bag is 2 lb/yd². The coats input is the number the sheet asks for, usually two. Wastage covers substrate porosity, the mix left in the bucket and the pot life; 10% is the starting point. The bag size and the price per bag set the order and the cost, and a price of zero shows quantities only.
On-site considerations
The data sheets agree on three things that move the quantity. The substrate is cleaned, roughened where it is smooth and pre-wetted so the first coat can be brushed in to fill the pores, and that first coat uses the most material. The second coat goes on crosswise after the first has set but within the window the sheet gives, so the batches are sized to the pot life, around an hour for the SikaTop product at 30 °C and shorter in heat. And on the outside the coating runs from finished grade down to the top of the footing, which is the extent IRC R406 describes, so the area is the wall and not the footing.
Using this alongside other BuildMetricLab tools
A liquid-applied membrane by the gallon is sized with the liquid rubber calculator, and a crystalline slurry with the crystalline waterproofing calculator. The footing drain that goes with the coating is in the weeping tile calculator and the French drain calculator. All BuildMetricLab tools run in your browser with no sign-up, and the formula is on the page so the maths can be checked.
Sources & methodology
Wall area = foundation perimeter × wall height. Total rate = first-coat rate + (coats − 1) × later-coat rate. Coating mass = area × total rate; wastage % added; bags = mass ÷ bag size, rounded up; coverage per bag = bag size ÷ total rate. US inputs in ft, lb/yd² and lb are converted to m, kg/m² and kg first (1 lb/yd² = 0.5425 kg/m²). References: IRC 2021 R406.1 and R406.2 (extent from finished grade to the top of the footing or 6 in below the basement floor; acceptable waterproofing systems); Sika Thoroseal-581 data sheet (2 lb/yd² first coat, 1 lb/yd² second, 225 and 450 ft² per 50 lb bag, 1/16 in cured); Sika Thoroseal Plus data sheet (0.22 and 0.11 lb/ft², 35 lb pail); SikaTop-107 Seal data sheet (1.0 to 1.5 kg/m² per coat, two coats, 25 kg set); BS 8102:2022 Types A, B and C as summarised by Sika; Approved Document C 2013 paragraph 3.2.
- UpCodes, International Residential Code 2021 (Virginia adoption), R406 Foundation Waterproofing and Dampproofing: R406.1 dampproofing from finished grade to the top of the footing or 6 in below the basement floor; R406.2 waterproofing where a high water table or severe soil-water conditions are known, and the list of acceptable systems
- Sika, Sika Thoroseal-581 product data sheet: first coat 2 lb/yd² (1.1 kg/m²) = 225 ft² per 50 lb bag, second coat 1 lb/yd² (0.54 kg/m²) = 450 ft² per bag, total 3 lb/yd² (1.6 kg/m²) at 1/16 in cured; 50 lb bags and pails
- Sika, Sika Thoroseal Plus product data sheet: first coat 0.22 lb/ft² (1.07 kg/m²), 160 ft² per 35 lb pail; second coat 0.11 lb/ft² (0.54 kg/m²), 320 ft² per pail; yield depends on texture and porosity
- Sika, SikaTop-107 Seal product data sheet: consumption 1.0 to 1.5 kg/m² per coat by brush, a minimum of two coats, not more than 2 kg/m² per coat, 25 kg set, pot life about 60 minutes at 30 °C
- Sika UK, Basement waterproofing concept: BS 8102:2022 Type A barrier (external or internal, including post-applied waterproofing mortars and coatings), Type B integral and Type C cavity drainage, grades 1 to 3, and dual systems where risk is high
- HM Government, Approved Document C (2013 edition incorporating 2013 amendments), paragraph 3.2: where the water table can rise to within 0.25 m of the lowest floor, the ground should be drained or other effective means taken
- ASTM International, ASTM C836/C836M-18 Standard Specification for High Solids Content, Cold Liquid-Applied Elastomeric Waterproofing Membrane for Use with Separate Wearing Course: scope covers decks and walls subject to hydrostatic pressure
Frequently asked questions
Are foundation waterproofing calculator results accurate enough to order materials?
Yes, as a bag count for the coating itself. The sum is the one the data sheets use, wall area times the rate for each coat, and it reproduces Sika's printed figures: at 2 lb/yd² a 50 lb bag covers 225 ft² in one coat, which is what the Thoroseal-581 sheet says. The things outside the count are the primer, the fillets, the protection board and the drainage, and a porous wall that takes more than the sheet rate, which is what the wastage input is for.
What wastage percentage should I use?
10% to start. The sheets warn that yield depends on the texture and porosity of the surface, so a rough block or stone wall takes more than the printed rate and a smooth poured wall about the rate. The other losses are the mix left in the bucket when the pot life runs out and the first coat brushed into open joints. Raise it to 15 or 20% for block, old masonry or a first job; the bag rounding adds a little on top.
Does this replace professional advice?
No. It is a quantity estimate from the dimensions you enter. Whether a wall needs waterproofing or dampproofing, and how far down, is set by the ground conditions and the local rules: IRC R406 in the United States, BS 8102 in the United Kingdom and Approved Document C in England. Below-grade waterproofing is a design, with drainage, protection and details, and failures are expensive to reach. For work that affects structure, gas, electrics, plumbing or drainage to a public sewer, use a suitably qualified professional.
Can I change the unit prices?
Yes. The price is per bag or pail of the size you enter, and the cost row is that price times the number of bags, so it follows the product you intend to buy. Change the bag size to the pack on the shelf, 50 lb bags or 35 lb pails in the United States, 25 kg bags or sets elsewhere, and the count and the cost both update. Leave the price at zero to see quantities only.
Spotted something off?
Calculations or display — let us know.
Related tools
Calculators from other categories that planners often reach for next.













