BuildMetricLab

Windows & Doors

Window Energy Rating Calculator

Estimates a window's energy rating band (A++ to E) from its U-value, g-value and air leakage

Updated October 14, 2026 · Live

What this tool does

Estimates a window's energy rating band (A++ to E) from its whole-window U-value, g-value and air leakage.

Window Energy Rating Calculator: the UK energy index and band (A++ to E) from the whole-window U-value, g-value and air leakage you enter.

Inputs
W/m²K
m³/h·m²
Result

Window Energy Rating Band (A++ to E)

B

Energy Index
-9.0 kWh/m² per year (net loss over the heating season)
Solar Gain Term
+87.4 = 218.6 × g 0.40
Heat Loss Term
−96.5 = 68.5 × (U 1.40 + 0.0165 × L₅₀ 0.50)
Air Leakage Share
0.6 kWh/m² per year of the loss term
Inputs Are Whole-Window
g_window = g_glass × 0.9 × glass fraction; U for the 1,230 × 1,480 mm standard window (EN ISO 10077); L₅₀ at 50 Pa (BS EN 1026 / BS 6375-1)
Accuracy
A planning estimate of the UK scheme (GGF Datasheet 2.3): a certified rating needs simulated or tested whole-window inputs from the maker
Plain Estimate
From BrightScale Labs
Invoice maker
Quote at the door. Signed on the spot.
Estimates and invoices for trades, built while you are still in the room.
Scan to get
Get it onGoogle Play

People also use

Formula Used
R=218.6 g−68.5 (U+0.0165 L50)R = 218.6 \, g - 68.5 \, (U + 0.0165 \, L_{50})
RR
Energy index (kWh/m² per year); band A++ ≥ 20, A+ ≥ 10, A ≥ 0, B ≥ −10, C ≥ −20, D ≥ −30, E ≥ −50
UU
Whole-window U-value (W/m²K)
gg
Whole-window g-value (glass g × 0.9 × glass fraction)
L50L_{50}
Air leakage at 50 Pa (m³/h·m²)

How the window energy rating calculator works

This calculator applies the Window Energy Rating equation published by the Glass and Glazing Federation in Datasheet 2.3 (June 2020). It is the method behind the British Fenestration Rating Council rainbow label and the one Approved Document L names for windows that show compliance by band rather than by U-value. The energy index is 218.6 × g − 68.5 × (U + 0.0165 × L₅₀), in kWh per square metre of window per year for the UK climate.

The first term is solar gain. The whole-window g-value, g, is the fraction of the sun's energy that passes through the complete window, frame included, and the constant 218.6 turns it into useful winter heat. The second term is loss. U is the whole-window U-value in W/m²K, and 0.0165 × L₅₀ converts the air leakage at 50 Pa, in cubic metres per hour per square metre, into an equivalent U-value. A positive index means the window gains more over a heating season than it loses.

With the defaults (U 1.4, g 0.40, L₅₀ 0.5) the gain term is 87.4, the loss term 96.5 and the index −9.0 kWh/m² per year, which is band B. The bands in GGF Table 1 are A++ at 20 or more, A+ from 10 to just under 20, A from 0 to just under 10, B from −10 to just under 0, C from −20, D from −30 and E from −50. The current scheme has no letter below E, so an index under −50 is reported as below E.

Typical UK windows and doors inputs

The inputs are whole-window figures, not the centre-pane numbers on a glass datasheet. GGF Datasheet 2.3 defines the window g-value as the glass g-value multiplied by 0.9, for the angle at which sunlight actually strikes a window, and by the glass fraction, the share of the window that is transparent. A common low-emissivity double glazed unit has a glass g-value of 0.63, and with a 70 percent glass fraction that gives 0.63 × 0.9 × 0.70 = 0.397, the 0.40 default. The 0.63 glass figure and a frame factor of 0.7 are also what Approved Document L Table 1.1 uses for its notional dwelling.

A few worked points show the spread. A triple glazed window at U 0.8, g 0.50 and L₅₀ 0.1 scores +54.4, well inside A++. A good double glazed unit at U 1.2, g 0.40 and L₅₀ 0.5 scores +4.7, band A. An older double glazed window at U 1.6, g 0.38 and L₅₀ 1.0 scores −27.7, band D. Single glazing at U 4.8, g 0.76 and L₅₀ 3.0 scores −166.1, far below E. Air leakage matters less than people expect: every 1 m³/h·m² at 50 Pa adds 1.13 kWh/m² to the loss term, so even the loosest L₅₀ of 3.0 costs 3.4 kWh/m², the same as raising the U-value by 0.05.

What this tool does not do

It does not produce a certified rating. A BFRC or other licensed label is calculated by an approved simulator for a standard 1,230 × 1,480 mm window to EN ISO 10077, with the glass g-value measured to BS EN 410 and air leakage tested to BS EN 1026 or BS 6375-1. It does not rate roof windows or doorsets, which use different constants in the same datasheet. It ignores orientation, shading and summer overheating, and the index is a comparison figure for the UK climate rather than a forecast of your heating bill.

On-site considerations for window energy rating

The rating belongs to the standard window, so a small casement with a wider frame fraction will gain less sun than its label suggests, and a large fixed light will gain more. The air leakage figure is for the window itself and says nothing about the gap between frame and reveal, which is sealed and insulated on site. Replacement windows in England and Wales installed by a FENSA or CERTASS member can be self-certified under the Building Regulations; otherwise building control needs to inspect the work.

Building Regulations and compliance

Approved Document L Volume 1 (2021 edition, 2023 amendments) Table 4.2 sets the limit for new windows in existing dwellings at 1.4 W/m²K or Window Energy Rating band B as a minimum, and its footnote 10 names GGF Datasheet 2.3 as the method for working out the band. The table's footnote 9 allowed timber windows 1.6 W/m²K or band C until 14 June 2023. The notional dwelling in Table 1.1 uses windows at 1.2 W/m²K.

Other countries rate windows differently. The United States and Canada use the NFRC label, which lists U-factor, solar heat gain coefficient and air leakage as numbers rather than a letter, and Australia's WERS scheme gives star ratings for heating and cooling. To use a US figure here, multiply the U-factor in Btu/h·ft²·°F by 5.678 to get W/m²K, so U-factor 0.30 is about 1.70 W/m²K. The solar heat gain coefficient is the same quantity as the whole-window g-value. US air leakage is quoted in cubic feet per minute per square foot at 75 Pa and is not directly comparable with L₅₀ at 50 Pa, so it stays a separate check.

Before you order

Ask the supplier for the certified rating document for the exact frame, glass specification and opening type you are buying, and compare it with the band here. If their index differs from this estimate, the usual reason is that you entered a centre-pane U-value or a glass g-value where the equation wants whole-window figures. Check that the quote states the whole-window U-value and g-value, and that the window carries the licensed scheme's label rather than a manufacturer's own claim.

Adjusting the defaults

The U-value field accepts 0.5 to 6 W/m²K, which covers triple glazing through to single glazing. The g-value accepts 0.1 to 1 and the air leakage 0 to 3 m³/h·m². Changing the U-value has by far the largest effect: with g at 0.40 and L₅₀ at 0.5, the window needs a U-value of about 1.27 W/m²K or better to reach band A, and only a higher g-value, from a larger glass fraction or clearer glass, lifts a 1.4 window out of band B. The result updates instantly, and the three lines under the band show the gain term, the loss term and how much of the loss comes from air leakage.

Using this window energy rating calculator alongside other BuildMetricLab tools

Use the window area calculator to measure the openings, then take the U-value you settle on into the window energy savings calculator to turn it into kilowatt hours and money for your home. The rooflight daylight area tool covers glazed roof area, which Approved Document L limits separately. All BuildMetricLab tools run in your browser, with no sign-up and no data sent anywhere, and the formula is shown on the page so the maths can be audited.

Sources & methodology

Applies the Window Energy Rating equation from GGF Datasheet 2.3 (June 2020), the method used by the BFRC label and named in Approved Document L: energy index = 218.6 × g − 68.5 × (U + 0.0165 × L₅₀) in kWh/m² per year for the UK climate, where g is the whole-window g-value (glass g-value × 0.9 × glass fraction), U the whole-window U-value in W/m²K and L₅₀ the air leakage at 50 Pa in m³/h·m². Bands follow GGF Table 1: A++ at 20 or more, A+ from 10, A from 0, B from −10, C from −20, D from −30 and E from −50; anything lower is reported as below E. Inputs are validated (U above 0, g between 0 and 1, L₅₀ at least 0). A certified rating needs simulated or tested whole-window data for the standard 1,230 × 1,480 mm window.

Frequently asked questions

Are window energy rating calculator results accurate enough to order materials?

They are accurate for comparing options and for checking a supplier's claim, because the equation and band limits are the published GGF ones. They are not a certified rating. A label from the BFRC or another licensed scheme is calculated by an approved simulator from tested whole-window data for the standard 1,230 × 1,480 mm window, so base an order on that document, not on this page.

What wastage percentage should I use?

None. An energy rating is a performance figure for one window, not a quantity of material, so there is no wastage to allow for. What changes the answer is whether the three inputs are whole-window values: a centre-pane U-value is lower than the whole-window figure and a glass g-value is higher than the window g-value, and either mistake pushes the band up by one or two letters.

Does this replace professional advice?

No. It is a planning estimate of the UK Window Energy Rating. Showing compliance with Approved Document L, choosing glazing for a listed building or conservation area, or specifying windows for a new dwelling needs a designer, surveyor or building control officer, and the rating itself must come from a licensed scheme.

Can I change the unit prices?

There are no prices in this tool. The three inputs are the whole-window U-value in W/m²K, the whole-window g-value from 0 to 1 and the air leakage at 50 Pa in m³/h·m², all of which you can change. To put a cost on a better band, take the U-values into the window energy savings calculator.

Spotted something off?

Calculations or display — let us know.