BuildMetricLab

Windows & Doors

Rooflight & Skylight Daylight Area Calculator

Recommended rooflight area for good daylight

Updated October 14, 2026 · Live

What this tool does

Suggests a rooflight or skylight area from the roof or floor area and a target glazed fraction, reports where the fraction sits against the 15 to 20% planning rule and the 25% glazing cap, and shows the vertical window area that would give the same daylight.

Enter the roof or floor area and a target glazed percentage; the calculator returns the recommended rooflight area, where the fraction sits against the planning rule of thumb, and the vertical window equivalent.

Inputs
ft²
%
Result

Recommended Rooflight Area

48.0 ft²

Roof Area
320 ft²
Target Glazed Fraction
15% of the area: within the 15 to 20% of floor area that VELUX suggests for a bright living space
Vertical Window Equivalent
about 96.0 ft² of vertical window for the same average daylight (a roof window gives more than twice the daylight factor of a vertical window of the same size, Danish Building Research Institute 2003)
Note
A planning fraction, not a daylight calculation: orientation, obstructions, glass transmittance and room depth change the result, and large rooflights need solar-control glass or shading in summer

Diagram

48 ft²² rooflight
Plain Estimate
From BrightScale Labs
Invoice maker
Quote at the door. Signed on the spot.
Estimates and invoices for trades, built while you are still in the room.
Scan to get
Get it onGoogle Play

People also use

Formula Used
Arl=Aroof×p100A_{rl} = A_{roof}\times \dfrac{p}{100}
AroofA_{roof}
Roof / floor area
pp
Target glazed fraction

A rooflight planned as a share of the floor it lights is the oldest rule in daylight design, and the easiest to check: multiply the area by the fraction. This calculator does that, tells you which side of the usual planning range your fraction falls, and shows how much vertical window the same daylight would take, so you can see what the overhead glass is buying.

How the rooflight & skylight daylight area calculator works

The recommended rooflight area is the roof or floor area multiplied by the target glazed fraction. With the defaults, 30 m² at 15% is 4.5 m² of rooflight; 320 ft² at 15% is 48 ft². The 15 to 20% of floor area is VELUX's planning guidance for a comfortable, bright living space, to be refined with an EN 17037 daylight analysis at design stage, and the calculator reports whether your fraction sits below it (a utility, corridor or bathroom level), inside it, above it, or above 25%, where England's Approved Document L asks for compensating energy measures when a window is added or enlarged. The last row turns the rooflight into its vertical-window equivalent at twice the area: a Danish Building Research Institute study (Dubois, Sørensen, Traberg-Borup and Johnsen, 2003) simulated the same room under overcast and sunny skies with a roof window, a vertical window and a dormer window of the same size and found the roof window gave more than twice the average daylight factor of the vertical window and more than three times that of the dormer. VELUX's own figures are the same, double for a sloped roof window and up to three times for a flat-roof one, because a rooflight sees the whole sky rather than a slice of it.

What you enter

The area is the roof plane or the floor of the room beneath it; for a flat roof the two are the same, and for a pitched one the floor is the better basis because VELUX's 15 to 20% figure is a share of floor area. Enter the room, not the house: a 12 m² (130 ft²) kitchen and a 30 m² (320 ft²) living room each get their own fraction. The fraction is a percentage of that area, from 5% to 40% on the slider. Around 10% lights a hallway or a bathroom; 15 to 20% is the living-space range; beyond 20% the gains are in brightness at the cost of summer heat and winter loss, and beyond 25% a code check in England and an overheating check almost anywhere. For an extension with a glazed wall as well, count the wall glazing in the total before deciding the rooflight share, since the 25% cap and the overheating sum are for all the glass together.

Reading the result

The headline is a glazed area to split into standard rooflight sizes: 4.5 m² is three roof windows of 1.14 × 1.40 m (1.6 m² each) with a little over, or one large flat rooflight of 1.5 × 3 m. The vertical-window equivalent row says what that daylight would cost in wall glazing, 9 m² for the default, which is why a rooflight in a deep extension does what a run of patio doors cannot. Spread the glazing rather than bunching it: two rooflights at either end of a long room give more even light than one large unit in the middle, and a rooflight towards the back of a deep room, away from the glazed wall, is the one that removes the gloom. The result is an area, not a daylight factor; it tells you how much glass the rule of thumb wants, not what illuminance the room will reach.

Safe by design

This tool sizes glazing area. It does not size the structural opening, the trimmers, the lintel or the roof members cut to make it, which is a structural engineer's calculation, and it does not design the flashing, the upstand or the kerb that keep the water out. A rooflight in a flat roof that people may walk near needs non-fragile glazing or protection, and any rooflight that opens needs a safe way to reach it. The electrics for an electric opener and the fall protection for the installer are for the trades concerned.

Assumptions and limits

The fraction is a planning rule of thumb, not a daylight calculation. The daylight a room actually receives depends on orientation, obstructions outside, the transmittance of the glass (a triple-glazed, solar-control unit lets through markedly less than clear double glazing), the depth and reflectance of the room, and whether the rooflight is a clear opening or sits at the bottom of a deep, splayed light well. EN 17037, the European standard for daylight in buildings, assesses rooms on the illuminance they reach for a share of the daylight hours, and that is the test a design should pass, not a percentage. The glazed fraction is also the lever that drives summer overheating and winter heat loss in the same direction: the glass that doubles the daylight doubles the solar gain, which is why England's Part O limits glazing in new homes and why large rooflights are specified with solar-control glass, external blinds or openable units for purge ventilation.

Using it with the rest of BuildMetricLab

The window area calculator sums the wall glazing that counts alongside the rooflight in the 25% total, the window energy rating calculator checks the glass specification for heat loss and solar gain, and the triple-pane window savings calculator puts a figure on the conduction through it. Every BuildMetricLab tool runs entirely in your browser, nothing you type is sent to a server, and the formula is shown on the page so the maths can be audited.

Sources & methodology

Rooflight area = roof (or floor) area × target fraction. The fraction is banded against VELUX's planning guidance of 15 to 20% of floor area for a comfortable living space (to be refined with an EN 17037 daylight analysis) and against the 25% of dwelling floor area at which England's Approved Document L, Volume 1 (paragraph 10.5) asks for compensating energy measures when a window is added or enlarged. The vertical-window equivalent is twice the rooflight area, from the Danish Building Research Institute study (Dubois, Sørensen, Traberg-Borup and Johnsen, 2003, By og Byg Dokumentation 047) in which a roof window gave more than twice the average daylight factor of a vertical window of the same size and more than three times that of a dormer. Imperial areas are converted at 0.09290304 m² per ft² before the calculation. The result is a planning area, not a daylight-factor or EN 17037 calculation, and the fraction is bounded above 0 and at 100%.

Frequently asked questions

How much rooflight is enough?

As a planning figure, 15 to 20% of the floor area for a living space, which is VELUX's guidance for a bright, comfortable room, refined at design stage with an EN 17037 daylight analysis; a hallway, bathroom or utility room is fine at around 10%. With the defaults that is 4.5 to 6 m² of rooflight for a 30 m² room, or 48 to 64 ft² for 320 ft². Above 20% the room gets brighter but the summer gain and winter loss climb with it, and above 25% of the dwelling's floor area for all glazing together England's Approved Document L asks for compensating energy measures.

Are rooflights better than windows for daylight?

Per square metre, yes, by a factor of about two. A Danish Building Research Institute study (Dubois, Sørensen, Traberg-Borup and Johnsen, 2003) simulated one room with a roof window, a vertical window and a dormer window of the same size and found the roof window gave more than twice the average daylight factor of the vertical window and more than three times that of the dormer, because it sees the whole sky rather than a slice of it. VELUX quotes double for a sloped roof window and up to three times for a flat-roof unit. The calculator's vertical-window equivalent row uses the factor of two.

Will a big rooflight overheat the room?

It can: the glass that doubles the daylight doubles the solar gain, and overhead glass catches the high summer sun that a vertical window misses. England's Part O (overheating) limits glazing in new homes for that reason. Above the 15 to 20% range, specify solar-control glass, external blinds or shading, and an opening unit for purge ventilation; in a hot climate a smaller fraction with a light well or diffusing glass does the job with less heat.

Is this a daylight-factor calculation?

No. It applies a planning fraction to an area and reports where the fraction sits against the rule of thumb and the 25% cap. A daylight-factor or EN 17037 study models the room's orientation, external obstructions, the transmittance of the glass, the depth and reflectance of the room and any light well, and judges the result on the illuminance reached for a share of the daylight hours. The area here is the starting point for that study, not its answer.

Spotted something off?

Calculations or display — let us know.