Timber & Framing
Staircase Set-Out Calculator
Risers, going, stringer length and pitch from a floor-to-floor rise
Updated July 9, 2026 · Live
What this tool does
Divide a floor-to-floor rise into equal risers, then set out the going, total run, stringer length and pitch for a straight flight of stairs.
Staircase Set-Out Calculator — divides your floor-to-floor rise into equal risers and returns the going, stringer length and pitch for a straight flight of stairs.
People also use
Formula Used
Formula Used
How the staircase set-out calculator works
The calculator takes the floor-to-floor rise (finished floor to finished floor), the largest riser you will allow, and the tread going. The formulas are risers = ceil(rise ÷ maximum riser), riser height = rise ÷ risers, treads = risers − 1, run = going × treads, stringer = √(rise² + run²) and pitch = atan(rise ÷ run). With the US defaults, a floor-to-floor rise of 104 in (8 ft 8 in, 2,642 mm) and a 7¾ in limit give 104 ÷ 7.75 = 13.4, which rounds up to 14 risers. Each riser is 104 ÷ 14 = 7.429 in (7 7/16 in, 188.7 mm). That leaves 13 treads, and at a 10 in (254 mm) going the run is 13 × 10 = 130 in (10 ft 10 in). The stringer is √(104² + 130²) = 166.5 in (13 ft 10.5 in), the pitch is atan(104 ÷ 130) = 38.7°, and 2R + G = 2 × 7.429 + 10 = 24.9 in (631 mm).
With the metric defaults, a floor-to-floor rise of 2,600 mm (8 ft 6.4 in) and a 200 mm limit give 2,600 ÷ 200 = 13 risers of exactly 200 mm (7.87 in). That leaves 12 treads, and at a 250 mm (9.84 in) going the run is 12 × 250 = 3,000 mm (9 ft 10 in). The stringer is √(2,600² + 3,000²) = 3,970 mm (13 ft 0.3 in), the pitch is atan(2,600 ÷ 3,000) = 40.9°, and 2R + G = 2 × 200 + 250 = 650 mm.
Rounding up the riser count means no riser is taller than your limit. Dividing the rise equally means every riser is the same, which matters because uneven risers cause trips. A rise smaller than one riser limit is a single step with no run or pitch.
Risers, treads and the going
A straight flight has one more riser than tread, because the top riser lands on the upper floor, which is not counted as a tread. The going is the horizontal depth of a tread from one riser face to the next, not counting the nosing overhang. The run is the going times the number of treads. The stringer length is the diagonal along the line of the nosings, so it is the minimum board length before you add the depth needed below the housings, the top and bottom connections and a margin for cutting.
Getting a comfortable pitch
The sum 2R + G, twice the riser plus the going, is a stepping-comfort guide. Approved Document K for England gives the normal range as 550 to 700 mm (21.7 to 27.6 in), and the tool shows whether your result falls inside it. A smaller riser and a longer going is easier to climb but takes more floor space, and a steeper pitch saves space but is harder to climb and riskier to come down. The tool shows the pitch angle so you can judge the trade-off.
Set-out on site
Measure the finished rise carefully, because the error repeats across the whole flight: 3 mm out on every riser of a 13-riser flight is 39 mm at the top. Include floor finishes that are not yet laid. If the upper floor will gain a 20 mm finish or the lower floor a carpet, the first and last risers change, so adjust the rise or allow for it in the first and last step. Mark the riser height on a storey rod, and use the going to mark the treads along the stringer. A steel framing square with stair gauges transfers the riser and going to each housing. Cut one trial stringer and offer it up before cutting the rest.
Regulations and safety
The tool does the geometry, then runs a first check against a commonly cited set of limits. On metric pages it uses Approved Document K for England (2013 edition): for a private stair, a rise of 150–220 mm, a going of 220–300 mm and a pitch of no more than 42°, with at least 2 m of headroom above the pitch line and a handrail 900–1,000 mm above it. On US-units pages it uses the International Residential Code (IRC Chapter 3) figures of a riser no taller than 7¾ in (197 mm) and a tread at least 10 in (254 mm) deep. Check your edition and your local amendments, because limits vary between private, shared and public stairs. Scotland, Wales, Northern Ireland, Canada, Australia and other places have their own rules. The check is guidance, not an approval; confirm it with your building control body.
Stairs are a common place for falls in the home, and safety guidance is available from bodies such as the HSE on slips and trips. Fit handrails and guarding to the local rules, use non-slip nosings where wear is likely, and ask a suitably qualified professional about any load-bearing element, the opening and the trimming.
Using this alongside other BuildMetricLab tools
Pair the set-out with the concrete steps calculator for outdoor steps, and the rafter set-out calculator for the roof above. Everything runs in your browser, nothing is sent anywhere, and the formula is shown so you can check the math. Conversions follow NIST SP 811.
Sources & methodology
Straight-flight stair geometry. Risers = ceil(rise ÷ maximum riser), with a small tolerance so an exact division does not gain a riser. Riser height = rise ÷ risers; treads = risers − 1; run = going × treads; stringer = √(rise² + run²); pitch = atan(rise ÷ run); 2R + G = 2 × riser + going. A rise smaller than one riser limit is a single step with no run, stringer or pitch. Rise must be above zero, the riser limit at least 50 mm (2 in) and the going at least 100 mm (4 in); blanks are refused. The first check compares the result with the England private-stair limits in Approved Document K (rise 150–220 mm, going 220–300 mm, pitch up to 42°) on metric pages, and with the IRC (riser up to 7 3/4 in, tread at least 10 in) on US-units pages. It is guidance only. Inches are shown to the nearest 1/16 with the decimal alongside.
Frequently asked questions
How does the calculator decide the number of risers?
It divides your floor-to-floor rise by the maximum riser height you enter and rounds up, so every riser is at or below your limit. It then splits the rise equally across those risers to give the exact riser height. For 2,600 mm and a 200 mm limit that is 13 risers of 200 mm.
Why is there one fewer tread than riser?
A straight flight has one more riser than treads. The top riser lands on the upper floor, which is not counted as a tread, so treads = risers − 1.
What is the 2R + G figure?
Twice the riser plus the going is a stepping-comfort guide. Approved Document K for England gives the normal range as 550 to 700 mm (about 21.7 to 27.6 in). It is guidance for a comfortable pitch and does not replace the riser, going and pitch limits in your local building code (for example the IRC).
What is the stringer length used for?
The stringer length is the straight-line distance along the line of the nosings. It is the minimum board length: the board also needs the depth below the housings or notches for strength, plus allowances for the top and bottom connections and for cutting.
Spotted something off?
Calculations or display — let us know.