Solar Sizing
Solar Array Sizing Calculator
Size the array and panel count for a target daily energy need
Updated July 12, 2026 · Live
What this tool does
Turns a daily energy target into an array size in kW and a panel count, allowing for your local sun hours and system losses.
Enter the daily kWh you need, your peak sun hours, a losses allowance and the panel wattage; the calculator returns the array size and how many panels it takes.
People also use
Formula Used
Formula Used
How the solar array sizing works
The formula is array kW = daily kWh ÷ (peak sun hours × (1 − losses)), and panels = ceil(array watts ÷ panel watts). With the defaults, 10 kWh a day, 4 peak sun hours and 20% losses, the array is 10 ÷ (4 × 0.8) = 3.125 kW, shown as 3.13 kW. Dividing 3,125 W by 430 W gives 7.27, which rounds up to 8 panels. Eight panels install 8 × 430 = 3,440 W, or 3.44 kW, and on an average day they would make 3.44 × 4 × 0.8 = 11.0 kWh, which is 110% of the need. Panels are about 2 m² (21 ft²) each at this size, so eight need roughly 16 m² (172 ft²) of roof; check the data sheet for yours.
A peak sun hour is one hour of sunlight at 1,000 W/m². The number of peak sun hours in a day equals the day's solar energy in kWh/m², so a site with 4 peak sun hours receives 4 kWh/m² a day.
What you enter
Enter the daily energy you need, the peak sun hours at your site, the losses and the panel wattage. Find daily energy from a year of bills (total kWh ÷ 365) or by adding up appliance loads. A household using 3,650 kWh a year uses 10 kWh a day. For sun hours, use a solar-resource tool for your location: PVGIS from the European Commission's Joint Research Centre and the Global Solar Atlas cover most of the world. Enter the figure for your panel tilt and compass direction, and the system losses from your installer's quote if you have one.
Panel wattage changes the count but not the array size. The same 3.125 kW needs 8 panels of 430 W, 9 panels of 350 W (3,125 ÷ 350 = 8.93, rounded up), or 7 panels of 500 W (6.25, rounded up). The installed capacity is then 3.44, 3.15 or 3.50 kW. Larger panels mean fewer to mount, but check that they fit the roof layout.
Reading the result
The headline is the array size in kW. The panel count rounds up, and the installed capacity and the average-day output show what that whole number of panels delivers. Because the array is sized on an average, the result suits a grid-connected system over a year. For a stand-alone system, size on the worst month, because the array has to cope with the lowest sun. If your worst month gives 1.5 peak sun hours rather than 4, the same 10 kWh needs 10 ÷ (1.5 × 0.8) = 8.33 kW, more than twice the default. A bigger household, say 20 kWh a day at 3.2 hours and 25% losses, needs 20 ÷ (3.2 × 0.75) = 8.33 kW, or 21 panels of 400 W.
Safe by design
This calculator does the arithmetic of sizing. It stops where a certified installer must sign off. It does not give cable or fuse sizes, earthing, battery charge settings or roof loads, because a wrong number in those can cause a fire, an electric shock or a collapse. All electrical work must be done by a qualified, certified installer. In the United States, Article 690 of the National Electrical Code covers solar systems, and your local authority normally inspects the installation. Other countries have their own codes and schemes. The US Department of Energy homeowner guide gives a plain-language overview of going solar.
Assumptions and limits
Nothing time-sensitive is built in. Electricity prices, export rates and local sun hours change and differ by place, so you enter your own. Peak sun hours are a long-run average; a run of dull days is a battery job, not an array job. The losses figure is one lumped number, and it does not include shading from trees or chimneys, a roof that faces away from the sun, or a very steep or flat tilt. If those apply, raise the losses or use a sun-hours figure for your actual orientation. Panels also lose a little output each year, commonly a fraction of a percent, so the array you buy today will make slightly less in ten years. The array is sized to your use, not to the roof, and it assumes you have the space.
Plan for the practical gaps between the result and a quote. A system needs more than panels: an inverter, mounting, cabling, isolators and metering, plus a grid-connection approval where the system feeds the grid. Ask for a written design that states the expected annual output in kWh, the assumed losses, and the roof direction and tilt. Compare that output with this tool's average-day figure times 365; a large gap means a different sun-hours or losses assumption, and it is worth asking why.
Using it with the rest of BuildMetricLab
Check the other half of the system with the inverter sizing calculator, size a battery with the battery bank calculator, and price a generator backup with the generator calculator. Everything runs in your browser, nothing is sent anywhere, and the formula is shown so you can check the math. Conversions follow NIST SP 811.
Sources & methodology
Array kW = daily kWh ÷ (peak sun hours × (1 − losses ÷ 100)). Panels = ceil(array W ÷ panel W), with a small tolerance so an exact fit does not gain a panel. Installed capacity = panels × panel W. Average-day output = installed kW × peak sun hours × (1 − losses). A peak sun hour is one hour at 1,000 W/m², so peak sun hours equal daily irradiation in kWh/m². The result is an annual-average sizing; stand-alone systems should use the worst-month sun hours. Daily energy, sun hours and panel wattage must be above zero, sun hours no more than 12, and losses from 0% to under 100%; blanks are refused. No tariffs, prices or sun-hours database is embedded.
Frequently asked questions
What are peak sun hours?
Peak sun hours are the equivalent hours a day of full 1,000 W/m² sunlight, which is the same number as the day's solar energy in kWh/m². Annual averages are roughly 2–3 in northern Europe, 4–5 in southern Europe and much of the US, and 5–6 in India and the Middle East. Look up your own site and panel direction in PVGIS or the Global Solar Atlas, and use the worst month for an off-grid system.
Why round the panel count up?
Panels come in whole units, so a fractional requirement rounds up to the next whole panel. The result shows the installed capacity and the average-day output that the whole number gives you, so you can see how far above the need it lands.
What losses figure should I use?
A combined 15–25% covers wiring, heat, dirt, inverter conversion and mismatch for most roof systems. Raise it for hot climates, long cable runs, heavy dirt or partial shading. Use 0% only to see the ideal case, which no real system reaches.
Does a bigger array always help?
Only up to the point your inverter, battery and the grid connection can use it. In some places the grid operator limits the size of a home system or the power it may export. Size the array to your load, then check the inverter and battery before you buy.
Spotted something off?
Calculations or display — let us know.