Masonry & Brickwork
Lintel Bearing Length Calculator
Works out the minimum lintel length for an opening, and the stock or modular length to order
Updated September 28, 2026 · Live
What this tool does
Works out how long a lintel must be for a masonry opening: the opening width plus the minimum bearing at each end, with the stock (metric) or modular (US block) length to order. It does not size the lintel for load.
Bearing rules from England's Approved Document A (metric) and the Concrete Masonry & Hardscapes Association (US block); stock lengths from a published UK steel lintel range.
What this tool does not check
- Does not select the lintel type or size, or check load capacity or deflection.
- Does not assess point loads, padstones, or openings close to corners or other openings.
- Local codes and the manufacturer may require more bearing than the minimum shown.
People also use
Formula Used
Formula Used
How the lintel bearing calculator works
A lintel is the beam over a door or window opening. Its ends rest on the masonry either side, and that overlap, the bearing, is what carries the load down into the wall. Too little and the masonry under the end is overstressed. So the first question for any lintel is how long it has to be: the clear width of the opening plus the minimum bearing at each end, L = W + 2b.
Enter the opening width. The calculator applies the minimum bearing for the unit system you pick, gives the minimum length, and then the length you would actually order, because lintels are made in fixed steps. It does not choose the lintel type or check its strength. That comes from the manufacturer's load tables or an engineer, and it matters more than the length.
Measuring the opening
Measure the clear structural opening from masonry to masonry at the level where the lintel will sit. It is not the size of the door or window frame, which fits inside the opening with a gap around it. If the reveals are not square, use the widest measurement.
Minimum bearing in England
Approved Document A, the structural guidance for England, says in paragraph 2C24 that lintel bearings should be 150 mm or more, and may be reduced to 100 mm where the clear span is 1200 mm or less. The metric side uses exactly that: 100 mm each end up to 1200 mm, 150 mm above. A 900 mm opening therefore needs at least 900 + 2 × 100 = 1100 mm of lintel.
In practice most lintels are ordered with 150 mm each end anyway. Catnic's lintel size guide works out lintel length by allowing 150 mm bearing at each end (its example is an 1800 mm lintel for a 1500 mm opening), and its product load tables are based on 150 mm end bearings. A lintel sat on 100 mm is shorter than the one the load figures describe.
Stock lengths
Steel lintels come in set lengths. On the product pages of that UK range, standard lengths rise in 150 mm steps up to 3000 mm and in 300 mm steps above, up to 4800 mm for many types (4575 mm is made, 4500 mm is not). The calculator adds 150 mm each end to the opening and rounds up to the next stock length: 1200 mm for a 900 mm opening, 2700 mm for 2400 mm, and 3600 mm for a 3200 mm opening, which leaves 200 mm at each end. Openings wider than 4500 mm fall outside that range and need a specialist or heavy-duty section.
Minimum bearing for US block walls
For concrete masonry in the US, the Concrete Masonry & Hardscapes Association's TEK 17-02A advises specifying a modular lintel length of at least the clear span plus 8 in, which gives at least 4 in of bearing at each end. The US side uses that 4 in minimum. Because block is laid in 8 in modules, it also rounds the length up to the next multiple of 8 in: a 36 in opening needs at least 44 in, which becomes a 48 in lintel with 6 in bearing each end. A 40 in opening needs exactly 48 in.
Steel angle lintels in brick veneer are sized by their own rules and span tables, and local codes may ask for more bearing than the minimum, so check both before ordering.
Worked examples
A 1.5 m patio door opening in England needs 150 mm each end, so at least 1800 mm of lintel, and 1800 mm is a stock length. A 1.2 m window can sit on 100 mm bearings, giving a 1400 mm minimum, but ordered for 150 mm bearings it becomes a 1500 mm lintel. In a US block wall, a 6 ft (72 in) opening needs at least 80 in, which is already a multiple of 8 in, while a 5 ft (60 in) opening needs 68 in and is ordered as 72 in, with 6 in bearing each end.
What the bearing length does not tell you
Length is the easy part. The lintel also has to suit the wall (single leaf, cavity or solid wall), carry the load above it (masonry, floors, roof and any point loads from beams) and deflect no more than the finishes allow. Point loads near the end of a lintel, long spans, and openings close to corners or other openings need an engineer, and sometimes a padstone under the bearing. The calculator deliberately stops at length.
Using this calculator with other BuildMetricLab tools
The brick and brick tie calculators cover the walling around the opening, and the brick arch calculator is the alternative for an arched head. All BuildMetricLab tools run in your browser with no sign-up, and every formula is shown on the page so the maths can be checked.
Sources & methodology
Minimum lintel length = clear opening + 2 × minimum bearing. US: 4 in each end, rounded up to an 8 in module (CMHA TEK 17-02A). Metric: 100 mm each end for clear spans up to 1200 mm, otherwise 150 mm (Approved Document A 2C24). Stock length: opening + 2 × 150 mm rounded up to the next standard length (150 mm steps to 3000 mm, then 300 mm to 4800 mm, per Catnic). The lintel is not sized for load.
Frequently asked questions
Are lintel bearing length calculator results accurate enough to order materials?
For length, yes: the minimum length follows exactly from the opening width and the bearing rule, and the stock or modular length is the next size up. What it cannot tell you is which lintel to buy. The type and strength come from the manufacturer's load tables or an engineer.
Does this calculator include a wastage or offcut allowance?
No. It works out a length, not a quantity. Lintels are bought as single pieces in set lengths, so the calculator rounds up to the next stock length (metric) or 8 in module (US block) instead of adding a percentage.
Is this tool a substitute for professional structural advice?
No. A lintel is a structural element. The length here is only the first check; the lintel type, its load capacity, and any padstones or point loads need the manufacturer's tables or a chartered or licensed structural engineer, and the work may need building control or permit approval.
Does this tool size or select the lintel itself?
No. It reports the minimum length and the bearing at each end. The lintel's type (for a cavity, solid or single-leaf wall) and its capacity for the masonry, floor, roof and point loads above must be chosen from the manufacturer's load tables or by an engineer.
Why use 150 mm bearings when 100 mm is allowed?
Approved Document A allows 100 mm where the clear span is 1200 mm or less, but manufacturers such as Catnic base their load tables on 150 mm end bearings and size lintels by adding 150 mm to each end. Ordering for 150 mm keeps the lintel within the conditions its load figures assume.
Spotted something off?
Calculations or display — let us know.
Related tools
Calculators from other categories that planners often reach for next.