BuildMetricLab

Insulation & Energy

Spray Foam Calculator

Spray foam board feet, kits, R-value and passes from area, thickness and foam type

Updated October 2, 2026 · Live

What this tool does

Works out the spray foam a wall, roof or floor needs in board feet and cubic metres from the area and thickness, with an overspray allowance and kit count. It also gives the R-value of open-cell or closed-cell foam, the passes it goes on in and the cost.

Area times thickness gives the board feet and volume; an overspray allowance sizes the kits; open-cell or closed-cell sets the R-value and passes.

Inputs
ft²
in
%
$
bd ft
Result

Spray Foam Required

1,890 bd ft

Type
Open-cell (about 0.5 lb/ft³, 8 kg/m³)
Volume
157.5 ft³ (4.46 m³)
With 10% Overspray
2,079 bd ft
R-value of the Foam Only
R-12.6 (R-3.6 per inch)
Passes (open-cell to full depth, up to 10 in)
1
Estimated Cost (board feet × rate)
$1,134.00
Fire Protection (IRC R316)
1/2 in gypsum lining, or an ignition barrier in attics and crawl spaces
Price it on PlainEstimate

Opens these materials as a new estimate on PlainEstimate, our free estimate and invoice app.

Plain Estimate
From BrightScale Labs
Invoice maker
Quote at the door. Signed on the spot.
Estimates and invoices for trades, built while you are still in the room.
Scan to get
Get it onGoogle Play

People also use

Formula Used
bd ft=A×d,V=bd ft12 ft3R=d×Rin\begin{aligned} \text{bd ft} &= A \times d,\quad V = \tfrac{\text{bd ft}}{12}\ \text{ft}^3 \\ R &= d \times R_{\text{in}} \end{aligned}
AA
Area to spray (ft²)
dd
Foam thickness (in)
RinR_{\text{in}}
R-value per inch: 3.6 open-cell, 6 closed-cell (k 0.040 and 0.024 W/mK)
VV
Foam volume installed; the overspray allowance is added for the kit count

How the spray foam calculator works

Spray foam is measured in board feet: one square foot of surface covered one inch deep. The kits are American, so the unit travels with them, and a 600 board foot kit means the same thing in Leeds or Melbourne as in Ohio. Multiply the area by the thickness in inches and you have the board feet. 540 ft² at 3.5 in is 1,890 board feet. The metric side does the same sum: 50 m² at 100 mm is 5.00 m³ of foam, or 2,119 board feet (a cubic metre is 423.8 board feet). The calculator shows both so a kit can be sized either way.

Spraying never lands every drop on the wall. Some foam goes on the floor sheet, some is trimmed flush with the studs, and a kit's last few board feet stay in the tanks. The overspray allowance adds that on top of the installed volume, and the kit count is worked out from the larger figure. The cost follows the way the foam is bought. An installer quotes for foam on the wall, so without a kit size the cost is the installed board feet (or, on the metric side, the area) times the rate. A kit buyer pays for whole kits, so once a kit size is entered the US cost is the kits bought times their board feet times the rate.

Open-cell and closed-cell

The two foams are different materials, not two grades of one. The US Department of Energy's Building America guide to spray foam gives open-cell a density of about 0.5 lb/ft³ (8 kg/m³) and an aged R-value of about 3.6 per inch. Closed-cell is about 2 lb/ft³ (32 kg/m³) and R-6 per inch. In metric terms that is a thermal conductivity of about 0.040 W/mK for open-cell and 0.024 W/mK for closed-cell, so 100 mm of open-cell is R 2.50 m²K/W and 100 mm of closed-cell R 4.17 m²K/W. The calculator uses those figures for the R-value row, for the foam layer alone. A wall or roof U-value also needs the other layers and the surface resistances, and the installer's product data sheet gives the exact values for the foam they spray.

Open-cell stays soft, lets water vapour through (the guide gives about 10 perms at 5 in) and soaks up liquid water, so it suits interior walls and the underside of a dry roof deck where the assembly can dry. Closed-cell is rigid, adds racking strength and is a vapour retarder at around 2 in, so it is the one for crawl spaces, rim joists, below-grade walls and anywhere water may reach. It costs more: the DOE guide put closed-cell at about three times the installed price per board foot, and about 60% more for the same R-value, since it gives about 1.7 times the R-value for the same thickness. It earns that where the strength, the water resistance or a tight cavity matter.

Passes

The DOE guide notes that closed-cell is limited to layers of 2 to 3 in per pass, with greater thicknesses built up in several layers. The reason is the heat of the reaction, and the product's data sheet gives the wait between lifts. Open-cell can go on to its full depth in one pass, generally up to 10 in (254 mm); the calculator counts a further pass for every 10 in beyond that. The calculator counts the passes from a 2 in (50 mm) lift for closed-cell, the lower end of that range. It matters for time on site, and because each lift is a separate chance to miss a spot.

How thick

The thickness comes from the R-value or U-value your code or energy assessment asks for, not from the calculator. In the US, Table N1102.1.3 of the International Residential Code (the IECC table) sets ceiling insulation at R-49 in climate zones 2 and 3 and R-60 from zone 4 north. The page linked is Virginia's adoption; its ceiling values match the model code, but the wall column carries Virginia's amendments, so check your own state's table. R-49 is about 13.6 in of open-cell or 8.2 in of closed-cell by the per-inch figures above; in a 2×4 wall the 3.5 in cavity holds R-12.6 of open-cell or R-21 of closed-cell. In England, Approved Document L, Volume 1 sets the targets. Table 4.3 covers an existing roof or wall you are renovating or keeping. Its improved column is 0.16 W/m²K for the roof, 0.30 for a solid wall insulated inside or out and 0.55 for a filled cavity, with a lesser standard allowed where that is not feasible or would not pay back in 15 years. Table 4.2 covers a new or replacement element: 0.15 for a roof and 0.18 for a wall. A roof U-value of 0.16 needs about R 6.3 m²K/W in total (6.1 after the surface resistances), which is roughly 150 mm of closed-cell or 245 mm of open-cell if the foam does all the work. Australia and New Zealand set their minimums as total R-values by climate zone in the NCC and H1 respectively, and Canada in Part 9 of the National Building Code.

Fire protection and safety

Spray foam is combustible and has to be covered. IRC section R316.4 in Chapter 3 requires a thermal barrier of at least 1/2 in (12.7 mm) gypsum board, or 23/32 in wood structural panel, between foam plastic and the inside of the building. Sections R316.5.3 and R316.5.4 allow an ignition barrier instead in attics and crawl spaces that are entered only for maintenance, such as 1 1/2 in of mineral fibre or 1/4 in of wood structural panel. R316.5.11 lets foam up to 3 1/4 in thick on sill plates and rim joists go uncovered if it meets the flame-spread limits. In England, Approved Document B expects a lining with the right fire performance in habitable rooms, and the installer's BBA or equivalent certificate says what the product is approved for and how it must be covered.

One of the two components is an isocyanate (MDI), and spraying puts it into the air as mist and vapour until the foam has cured. The UK Health and Safety Executive says spraying produces very high exposures and that occupational asthma is a significant risk for the people doing it. Anyone generating isocyanate aerosols needs annual lung-function checks, with respiratory protection where ventilation cannot control the mist. Product data sheets ask everyone else to stay out of the building during spraying and for a set time after, often 24 hours or more. In UK roof spaces there is a further caution. The RICS consumer guide to spray foam insulation explains that foam sprayed to the underside of a roof hides the timbers from inspection and, if wrongly installed, can leave them wet behind the foam. It tells homeowners to check with their mortgage lender and insurer before installing it. Get that advice first.

Worked examples

A 2×4 exterior wall 60 ft long and 9 ft high, 540 ft², filled with 3.5 in of open-cell: 540 × 3.5 = 1,890 board feet, 2,079 with 10% overspray, so four 600 board foot kits. The foam is R-12.6 and goes on in one pass. At $0.60 a board foot the installed foam is $1,134, and the four kits, 2,400 board feet, are $1,440, which is what the card shows once a kit size is entered. A 400 ft² crawl space wall at 2 in of closed-cell is 800 board feet, R-12, one pass. A 1,200 ft² attic roof deck at 5.5 in of open-cell is 6,600 board feet, R-19.8, one pass, and needs an ignition barrier or a tested foam.

A 50 m² loft room at 100 mm of closed-cell: 5.00 m³, 2,119 board feet, R 4.17 m²K/W, two passes of 50 mm. With 10% overspray that is 5.50 m³, or 2,331 board feet, four 600 board foot kits. At £35 per m² installed the cost is £1,750. Note that 100 mm alone does not reach the 0.16 W/m²K roof figure; the rest of the build-up has to do the remaining work, or the foam has to be thicker.

What the calculator does not include

The thermal barrier or lining, the vapour control layer where open-cell needs one, and the ventilation gap a roof may need between foam and the deck are separate. So are cleaning, masking and removal of old insulation. The R-value row is the foam alone, not the wall or roof. Nothing here checks whether a particular roof or wall should be spray foamed at all; that is a question for the installer's certificate and, in the UK, for your surveyor.

Using this with other BuildMetricLab tools

The wall insulation cost calculator compares the finished cost of batts, boards and foam for a wall, and the air sealing calculator covers the gaps a foam job does not reach. The attic insulation calculator prices the loose-fill or batt alternative for a ceiling. All BuildMetricLab tools run in your browser with no sign-up, and the formula is on the page so the maths can be checked.

Sources & methodology

Board feet = area (ft²) × thickness (in); volume = area × thickness. Quantity to buy = volume × (1 + overspray %); kits = ceil(board feet to buy ÷ kit size). R-value of the foam alone = thickness × R per inch on US-units pages (3.6 open-cell, 6 closed-cell) or thickness ÷ k on metric pages (k = 0.040 and 0.024 W/mK), per the DOE Building America guide. No surface resistances or other layers are included. Passes = ceil(thickness ÷ 2 in or 50 mm) for closed-cell and ceil(thickness ÷ 10 in) for open-cell. Cost = installed board feet × rate, or kits × kit size × rate when a kit size is entered (US units); area × rate per m² (metric, whether or not a kit size is entered).

Frequently asked questions

Are spray foam calculator results accurate enough to order materials?

For the board feet and kit count, yes, provided the area and thickness are the installed ones and the overspray allowance suits the job; a kit's yield is rated at a set temperature and thickness, so check the maker's figure. The R-value row uses typical per-inch figures; the installer's data sheet gives the exact value for the product sprayed.

Does this calculator include a wastage allowance?

Yes, as the overspray allowance input, 10% by default. It covers foam lost to overspray, trimming flush with the framing and what stays in a kit's tanks, and the kit count is worked out from the quantity with the allowance. Installers quote for foam on the wall, so without a kit size the cost ignores the allowance; with a kit size on the US side the cost is the whole kits bought, so it does move with it. Set the allowance to 0 to see the bare volume.

Does this replace professional advice?

No. Spray foam is a two-part chemical applied by someone in breathing protection, and it must be covered by a fire-rated lining or, where the code allows, an ignition barrier. Whether a roof or wall should have it at all depends on how the assembly dries. Use the figures to size a job or check a quote, and have a certified installer confirm the product, thickness and detailing.

Can I change the unit prices?

Yes. The US side prices by the board foot, which is how installers and kits are sold there; the metric side prices per square metre installed at the thickness entered, which is how UK and Australian installers quote. Enter your own figure and the cost is recalculated.

Spotted something off?

Calculations or display — let us know.