BuildMetricLab

Kitchen

Kitchen Cabinet Run Planner

How many cabinets fit a wall run, and the filler

Updated July 12, 2026 · Live

What this tool does

Works out how many standard cabinets fit along a wall run once appliance gaps are taken out, and the width of filler panel left over.

Enter the wall length, the cabinet unit width and the total appliance gap; the calculator returns how many cabinets fit and the filler width.

Inputs
ft
in
ft
Result

Cabinets That Fit

5

Unit Width
24 in
Appliance Gaps
2.50 ft
Cabinets Fill
120 in
Filler Panel Needed
None, units fill the run
Run Length
12.50 ft

Diagram

5 units
Price it on PlainEstimate

Opens these materials as a new estimate on PlainEstimate, our free estimate and invoice app.

Plain Estimate
From BrightScale Labs
Invoice maker
Quote at the door. Signed on the spot.
Estimates and invoices for trades, built while you are still in the room.
Scan to get
Get it onGoogle Play

People also use

Formula Used
N=⌊L−gw⌋,filler=(L−g)−N wN = \left\lfloor \dfrac{L - g}{w} \right\rfloor, \quad filler = (L - g) - N\,w
LL
Wall length
gg
Appliance gaps
ww
Unit width (L, g and w in the same unit)

This calculator works out how many identical cabinets fit along a wall once the space for freestanding appliances is taken out, and how much filler panel is left to close the run. It runs in your browser and shows its working, so you can check every step against your own measurements.

How the kitchen cabinet run calculator works

The usable run is the wall length minus the gaps you leave for freestanding appliances. Dividing that by the cabinet unit width and rounding down gives the number of whole units that fit, and the remainder is the filler width: N = ⌊(L − g) ÷ w⌋ and filler = (L − g) − N × w.

The US default is a 12.5 ft (3.81 m) wall with a 2.5 ft (30 in, 0.76 m) gap for a range and 24 in (610 mm) cabinets. The usable run is 150 − 30 = 120 in, and 120 ÷ 24 = 5 cabinets with nothing left over. A 13 ft wall instead gives 156 − 30 = 126 in, which is still 5 cabinets but leaves a 6 in filler. The metric default is a 3.6 m wall with a 0.6 m appliance gap and 600 mm cabinets. 3,600 − 600 = 3,000 mm is exactly 5 units. At 3.7 m the same 5 units leave a 100 mm filler, and at 4.2 m the run takes exactly 6.

What you enter

Wall length is the distance from corner to corner along the wall, measured at worktop height, since walls are rarely square and plumb. Measure in two or three places and use the shortest, because cabinets cannot be squeezed in. Cabinet unit width is the width of the cabinet you plan to use. US base cabinets are commonly sold in 3 in steps from 9 to 48 in, and metric ranges commonly in widths such as 300, 400, 500, 600, 800 and 1,000 mm. Appliance gaps are the combined widths of anything standing in the run that is not a cabinet, such as a freestanding range or fridge. Built-in appliances such as a dishwasher sit in the cabinet line, so count each one as a cabinet width instead.

Reading the result

The cabinet count is the number of whole units that fit, and the filler row is the space left. A leftover of 20 mm (about ¾ in) or less can usually be absorbed in the end panels and scribed to the wall, and the result says so. A larger gap needs a dedicated filler panel or a wider cabinet from the range. The result assumes every cabinet is the same width. Real kitchens mix widths, so with a 100 mm gap you could replace one 600 mm unit with a 700 mm one, if the range offers it, in place of a filler. Check the supplier's unit sizes before you decide.

Safe by design

This tool plans layout and quantities only. It never sizes a gas connection or an electrical circuit, and both are regulated trades that a qualified, registered installer must carry out. That means a licensed electrician and, for gas, a Gas Safe registered engineer in the UK or a licensed gas fitter elsewhere. Appliances also need clearances and ventilation set by the manufacturer, so check the installation instructions for your model before you fix the cabinet positions.

Assumptions and limits

This plans a single straight run with identical units. Corners, tall larder units and integrated appliances change the packing, and worktop overhangs, end panels and door handles take a few millimetres. A corner cabinet adds a blind section that a straight-run count does not include. Run it once per wall and confirm against the supplier's unit schedule. The National Kitchen and Bath Association (NKBA) publishes kitchen planning guidelines for clearances and cabinet layout in the US, and other regions have their own recommendations, so check what applies to you.

Before you order, check the wall for flatness and the floor for level, since cabinets are set from the highest point of the floor and the gaps are filled with plinth and scribed panels. Allow a few millimetres at each end for scribing against uneven walls, and leave room for the doors and drawers to open past tall units, handles and adjacent runs. Order every cabinet in a run from the same range and batch, because finishes can differ between production runs, and confirm lead times for made-to-order sizes. If the numbers leave an awkward filler, move the appliance gap or choose a different cabinet width and run the calculator again.

Using it with the rest of BuildMetricLab

The cabinet door and drawer count, kitchen work triangle and appliance cut-out size calculators in the same category cover the next steps once the run is planned. Every BuildMetricLab tool runs in your browser with no sign-up and nothing sent to a server, and each one shows its formula so you can check the maths.

Sources & methodology

Usable run = wall length − appliance gaps. Cabinets = ⌊usable run ÷ unit width⌋, rounded down to whole units with a tiny tolerance so an exact fit is not lost. Filler = usable run − cabinets × unit width. A leftover of 20 mm (about ¾ in) or less is reported as small enough to absorb in the end panels. All cabinets are assumed to be the same width and the run to be straight. Corners, tall units and worktop overhangs are not modelled. A blank field is refused, and gaps that fill the whole wall are refused. Every result is calculated from the values you enter, all inputs are editable, and no time-sensitive prices or rates are embedded.

Frequently asked questions

What cabinet widths are standard?

US base cabinets are commonly sold in 3 in steps from 9 to 48 in (12, 15, 18, 24, 30, 33, 36 and 48 in are all common), and wall cabinets in similar widths up to 36 in. Metric ranges commonly offer widths such as 300, 400, 500, 600, 800 and 1,000 mm. Mixing widths lets a run fill a wall with a smaller filler.

What is a filler panel?

A narrow strip that closes the gap between the last cabinet and a wall or appliance, so the run finishes flush. This tool gives the width needed. A leftover of about 20 mm (¾ in) or less can usually be absorbed in the end panels.

Does this handle corners?

No. It plans one straight run of identical units. Corner and larder units change the packing, so run it for each wall and allow for the corner unit separately.

Should I plan around appliances?

Yes. Enter the total width you are leaving for freestanding appliances, such as a range or fridge, so the cabinet count fits the space that is actually left. Built-in appliances such as a dishwasher sit in the cabinet line, so count them as a cabinet width instead.

Spotted something off?

Calculations or display — let us know.